MODEL CR1451
CR-1453C is 208 Volt, CR-1453A is 230 Volt, CR-1453B is 460 Volt
60 Hz.50 Hz.
Induction Motor 1Ph, 5 H.P., 3450 RPM 1Ph, 3.5HP, 3450 RPM
Voltage 230 Volts 200-220 Volts
Amperage 21.0 17.0
Length 19-9/16
Electrical Service to Unit No. 10
Airflow @ 2" Opening 225 C.F.M. 5.4 CMM
Sealed Vacuum 105" H2O 245 H2O
Pump Regenerative
RECOMMENDED RELIEF VALVE SETTINGS 77" H2O 160.8 cm H2O
Dimensions
Length 18"
Width 16-3/8"
Height 16-5/8"
Remote Control Operated 24 Volt
Shipping Weight 148 lbs.


Primary Filter - DC-1200 w/Air Channel
Filtration Cyclonic funnel primary, standpipe secondary with safety screen and convenient lift off inspection lid.
Inlet and Outlet Connections 2"
Capacity 27 Qts
Diameter 14-1/8"
Height 37-1/4"
Radius including legs 15"
Shipping Weight 23.0 lbs.
Replacement Bag PB-4M


Secondary Filter - DC-500
Filtration HPB2H
Inlet and Outlet Connections 2"
Capacity 27 Qts.
Diameter 13-5/8"
Height 25-3/4"
Shipping Weight 10 lbs.
Replacement Bag HFB-4
Optional Bag Paper Bag HPB-1

* Electrical Service to unit should be installed by a licensed electrician.

NOTE: All commercial and industrial units should use 2-conducters, 18 gauge minimum for low voltage wiring (2VM-18001).

NOTE: Relief Valve should be set at a preferred setting of 80" H2O at 60 Hz. and 162 cm H2O at 50 Hz, when possible use the preferred/recommended settings above.

NOTE: The first 5 feet of metal tubing MUST be used on exhaust (SF-207).

(Upgrade to a DC-750 if fine dust control is required)